Company Profile
Products
 
UItimate Test Criteion
Modified Date2001/12/12Executive Date2002/01/01Reference. No.DF-SIP-1003.01Edition No.A/4
Battery TypeR03PDiscription1.Mercury free battery,W(Hg)≤1×10-4%; 2.Cadmium free battery,W(Cd)≤1×10-3%
1.Delivery Criterion (Shipment after meeting the following requirement)
No.Test ItemQuality CriterionMeasuring Equipment/MethodSampling/determinant methodNote
1External Diameter10.1-10.5mmThe accuracy of vernier caliper shall be ≥0.02mm

GB2828-87,IL=S-3
AQL=0.65

2Total height43.3-44.5mm
3Open circuit voltage1.660-1.725VThe accuracy of the direct voltage meter shall be ≥0.25%, and its internal resistance shall be ≥1MΩ,or digital multimeterGB2828-87,IL=I
AQL=0.65
Measuring environment temperature:20±2°C
4Short circuit current
≥2.5A
0.5 Grade Model C19 Current Meter
5Discharging time≥30minIDS battery intellegent discharge system, continuus discharge to 0.9V at 3.9Ω, record the discharge time, then discharge to 0.6V, observe the leakage-proof performance GB/T7112-1998 6.3
6Leakage-proof Performance

No transfiguration, no leakage shall occur.

GB2829-87,DL=III RQL(Ac,Re)=40(1,2)
7Appearance(eye test)a.Each battery is clear and neat and positive polarity is placed in the middle;
b.Integrity & neatness of trademark letters & signs. Uniformity of shrink &metallic jacket;
c.Copper cap & false bottom are clear and neat,with no rust.
GB2828-87, IL=I;AQL=1.5 (Light bug); AQL=0.65 (serious bug)
8Packaging(eye test)a.Shrink tube neat & well; b.Packing cotton, cotton material & printing quality meet requirement.GB2828-87, IL=1; AQL=1.5
9Other packaging requirementSales Department check according to Order Packaging Requirement for each order. 
10Order related stock and process inspection are finished and meet requirement. 
2. Tracing standard after delivery (at least once per month, not corresponding to order; Shelf life: 2 years)
Item End-point voltageGB/IEC StandardEnterprise Standard (new battery) ≥2 month≥6 month≥12 month18-24 month
Discharge standard3.9Ω continuous discharge0.9V ≥30min≥28min≥25min≥23min≥20min
5.1Ω,4min/h,8h/d0.9V≥45min≥60min≥58min≥56min≥54min≥50min
10Ω,1h/d0.9V≥84min≥120min≥118min≥115min≥110min≥100min
75Ω,4h/d0.9V≥20h≥22h≥22h≥20h≥18h≥18h
3.6Ω,15s/min,24h/d0.9V≥120≥130≥120≥110≥100≥100
Voltage & Current testOpen circuit voltage(V)+0.225
1.500-0
1.660-1.725≥1.640≥1.620≥1.600≥1.580
Voltage under load(V)3.9Ω ≥1.400≥1.380≥1.360≥1.320≥1.300
Short circuit current(A)≥2.5≥2.3≥2.1≥2.0≥1.8
3. Routime test item (at least once per month)
No.ItemTest RequirementTset MethodSampling &determinant method
1High Temperature TestNo transfigurqtion, no leakage shall occur. Constant temperature box/ Constant temperatur45±2°C, 720hGB2829-87,DL=III
50pcs of R12/time,RQL=5.0
 
Suzhou Industial Park East Battery Co.,Ltd.  Tel: 86-512-67540371   E-mail: mail@szebfbattery.com