| UItimate
Test Criteion | | Modified Date | 2001/12/12 | Executive
Date | 2002/01/01 | Reference. No. | DF-SIP-1003.23 | Edition
No. | A/1 | | Battery
Type | 6LR61 | Discription | 1.Mercury
free battery,W(Hg)≤1×10-4%; 2.Cadmium free battery,W(Cd)≤1×10-3% |
|
| 1. Delivery Criterion (Shipment
after meeting the following requirement) | | No. | Test
Item | Quality Criterion | Measuring
Equipment/Method | Sampling/determinant method | Note |
| 1 | Width | 24.5-26.5mm | The
accuracy of vernier caliper shall be ≥0.02mm |
GB2828-87,IL=S-3 AQL=0.65 |  |
| 2 | Thickness | 15.5-17.5mm |
| 3 | Total
height | 46.5-48.5mm | | 4 | Open
circuit voltage | 9.40-9.90V |
The accuracy of the direct voltage meter shall be ≥0.25%,
and its internal resistance shall be ≥1MΩ,or digital multimeter | GB2828-87,IL=I
AQL=0.65 | Measuring environment temperature:20±2°C |
| 5 | Voltage
under load(180Ω) | ≥9.0V |
| 6 | Appearance(eye test) |
a.Cleanness, with no rust and leakage, postive and negative end are well and
no distortion; b.Trade mark uniform and position moderate and obedient. | GB2828-87,
IL=I;AQL=1.5 (Light bug); AQL=0.65 (serious bug) |
| 7 | Packaging(eye test) | Packaging
box and cotton meet quality requirement | |
| 8 | Other dimentions | According
to QB/T 1186-1991 | | | 9 | Other
packaging requirement | Sales Department check according to
Order Packaging Requirement for each order. | |
| 10 | Order related stock and process
inspection are finished and meet requirement. | |
| 2. Tracing standard after delivery (at
least once per month, not corresponding to order; Shelf life: 2 years) |
| Item | End-point
voltage | GB/IEC Standard | Enterprise
Standard (new battery) | ≥2 month | ≥6
month | ≥12 month | 18-24
month | | Discharge standard | 180,30min/d,6d/w | 4.8V | ≥576min | ≥650min | 630min | 600min | 550min | 500min |
| 270,1h/d,6d/w | 5.4V | ≥12.0h | ≥16.0h | ≥15.5h | ≥15.0h | ≥14.5h | ≥14.0h |
| 620,2h/d,6d/w | 5.4V | ≥33.0h | ≥38.0h | ≥37.5h | ≥37.0h | ≥36.5h | ≥36.0h |
| | | | | | | |
| Voltage & Current test | Open
circuit voltage | 9.00-9.90 | 9.40-9.90 | ≥9.40 | ≥9.20 | ≥9.00 | ≥8.80 |
| Voltage under load(V)180Ω | | ≥9.00 | ≥8.95 | ≥8.90 | ≥8.70 | ≥8.50 |
| | | | | | | |
| 3. Routime test item (at least once per
month) | | No. | Item | Test
Requirement | Tset Method | Sampling
&determinant method | | 1 | High
Temperature Test | No transfigurqtion, no leakage shall occur.
| Constant temperature box/ Constant temperatur45±2°