1. Delivery Criterion (Shipment after the
following requirement )
No.
Test
item
Quality Criterion
Measuring
Equipment/Method
Sampleing/determinant method
Note
1
Length
65.0-67.00mm
The
accuracy of vernier caliper shall be≥0.02mm
GB2828-87,IL=S-3 AQL=0.65
2
Width
65.0-67.00mm
3
Total
height
108.0-115.0mm
4
Open
circuit votage
6.60-6.90V
The accuracy
of the direct voltage shall be ≥0.25%, and its internal resistance shall be
≥1MΩ,or degital multimeter
GB2828-87,IL=I
AQL=0.65
Measuring environment temperture:20±2°C
5
Short
circuit current
≥9.5A
0.5 Grade model
C19 Direct Current Meter
6
Dischanging
time
≥900min
IDS battery
intellegent discharge system, continuous discharge to 3.6V at 15.6Ω,record
the discharge time, then discharge to 2.40V,observe the leakage-proof performance
GB/T7112-1998
6.3
7
Leakage-proof
Performance
No transfiguration,no leakage shall occur.
GB2829-87,DL=III
RQL(Ac,Re)=40(1,2)
8
Appearance(eye
test)
a.Cleaness and brightness; b.Correct mark of
positive and negative polarity; c.Trade mark neat,fibula smooth and uniform,fluaction
moderate,direction right;