1. Delivery Criterion (Shipment after meeting
the following requirement)
No.
Test
Item
Quality Criterion
Measuring
Equipment/Method
Sampling/determinant method
Note
1
Length
60.0-62.0mm
The
accuracy of vernier caliper shall be ≥0.02mm
GB2828-87,IL=S-3 AQL=0.65
2
Width
20.0-22.0mm
3
Total
height
63.0-67.0mm
GB2828-87,IL=I
AQL=0.65
Measuring environment temperature:20±2°C
4
Open
circuit voltage
4.800-5.175V
The accuracy
of the direct voltage meter shall be ≥0.25%, and its internal resistance shall
be ≥1MΩ, or digital multimeter
5
Short
circuit current
≥6.5A
0.5Grade Model
C19 Direct Current Meter
6
Discharging
time
≥190min
IDS battery
intellegent discharge system, continuous discharge to 2.7V at 11.7Ω, record
the discharge time, then discharge to 1.05V, observe the leakage-proof performance
GB/T7112-1998
6.3
7
Leakage-proof
performance
No transfiguration, no leakage shall occur.
GB2829-87,DL=III
RQL(Ac,Re)=40(1,2)
8
Appearance(eye
test)
a.Clearness and brightness; b.Correct mark of positive
and negative polarity; c.Trade mark neat,fibula smooth and uniform,fluctuacton
moderate, direction right..