Company Profile
Products
 

Ultimate Test Criteion

Modified Date2001/12/12Executive Date2002/1/1Reference. No.DF-SIP-1003.12Edition No.A/3
Battery Type3R12CDiscription1.Mercury free battery,W(Hg)≤10-4%; 2.Cadmium free battery,W(Cd) ≤ 10-3%
1. Delivery Criterion (Shipment after meeting the following requirement)
No.Test ItemQuality CriterionMeasuring Equipment/MethodSampling/determinant methodNote
1Length60.0-62.0mmThe accuracy of vernier caliper shall be ≥0.02mm

GB2828-87,IL=S-3
AQL=0.65

2Width20.0-22.0mm
3Total height63.0-67.0mm
    GB2828-87,IL=I
AQL=0.65
Measuring environment temperature:20±2°C
4Open circuit voltage4.500-5.175VThe accuracy of the direct voltage meter shall be ≥0.25%, and its internal shall be ≥1MΩ, or digital multimeter
5Short circuit current≥6.0A0.5Grade Model C19 Direct Current Meter
6Discharging time≥145minIDS battery intellegent discharge system, continuous discharge to 2.7V at 11.7Ω, record the discharge time, then discharge to 1.80V, observe the leakage-proof performanceGB/T7112-1998 6.3
7Leakage-proof performanceNo transfiguration, no leakage shall occur. GB2829-87,DL=III
RQL(Ac,Re)=40(1,2)
8Appearance(eye test)a.Clearness and brightness; b.Correct mark of positive and negative polarity; c.Trade mark neat,fibula smooth and uniform,fluctuacton moderate, direction right..GB2828-87,IL=I;AQL=1.5(light bug)AQL=0.65(serious bug)
9Packaging(eye test)Packaging cotton material & printing quality meet requirement.GB2828-87,IL=I;AQL=1.5
10Other packaging requirementSales Department check according to Order Packaging Requirement for each order.
11Order related stock and process inspection are finished and meet requirement.
2. Tracing standard after delivery (at least once per month, not corresponding to order; Shelf life: 2 years)
Item
End-point voltageGB/IEC StandardEnterprise Standard (new battery) ≥2 month≥6 month≥12 month18-24 month
Discharge standard20Ω,1h/d2.7V≥4.5h≥5h≥4.8h≥4.6h≥4.5h≥4.0h
220Ω,4h/d2.7V≥96h*≥88h≥86h≥84h≥82h≥80h
11.70Ω,continuous discharge2.7V ≥145min≥140min≥135min≥125min≥115min
 
Voltage & Current testOpen circuit voltage(V)4.5004.500-5.175≥4.700≥4.600≥4.500≥4.400
Voltage under load(V)11.70Ω ≥4.500≥4.300≥4.100≥3.900≥3.600
Short circuit current(A)≥6.0≥5.8≥5.6≥5.4≥5.0
3. Routime test item (at least once per month)
No.ItemTest RequirementTset MethodSampling &determinant method
1High Temperature TestNo transfiguration, no leakage shall occur. Constant temperature box/ Constant temperatur45±2°C, 720hGB2829-87,DL=III
50pcs of R12/time,RQL=5.0
 
Suzhou Industial Park East Battery Co.,Ltd.  Tel: 86-512-67540371   E-mail: mail@szebfbattery.com